VALIDAÇÃO DE UM TESTE DE RESPIRAÇÃO ESPONTÂNEA PARA PREVER SUCESSO NA EXTUBAÇÃO DE RECÉM-NASCIDOS
dc.contributor.advisor | Celeste, Roger Keller | |
dc.contributor.coadvisor | Fonseca, Luciana Teixeira | |
dc.creator | Fiatt, Marciane Pesamosca | |
dc.date.accessioned | 2023-09-19T16:53:26Z | |
dc.date.available | 2023-09-19T16:53:26Z | |
dc.date.created | 2023-09-19 | |
dc.date.issued | 2019-06-10 | |
dc.description.abstract | Objetivo: Avaliar o Teste de Respiração Espontânea com pressão de suporte mínima para prever sucesso na extubação de recém-nascidos (RN) e identificar variáveis demográficas e clínicas relacionadas à falha na extubação. Desenho do estudo: Estudo de coorte observacional. Pacientes: RNs submetidos à ventilação mecânica invasiva por pelo menos 24h e com extubação programada. Métodos: Os RNs elegíveis foram submetidos ao teste no modo ventilatório de pressão positiva contínua nas vias aéreas com pressão de suporte mínima, por 10 minutos, antes de extubar, sendo monitorados durante este período e classificados como falha no teste na presença de algum destes critérios: bradicardia, queda na saturação de pulso de oxigênio, aumento no esforço respiratório ou apneia. O resultado do teste não foi comunicado. Resultados: Foram realizados 170 testes. Houve 143 extubações com sucesso, destas 138 também passaram no teste com sensibilidade de96,5% (IC95%: 92,0-98,8). Das 28 extubações que evoluíram com falha na extubação (16,4%),16 também falharam no teste com especificidade de 57,1%, (IC95%: 37,2-75,5). O valor preditivo negativo foi de 72,2% (IC95%: 52,5-91,0). O valor preditivo positivo foi de 92% (IC95%: 86,1-95,6). %. Nos RNs com IG ˃ 37 semanas e com peso ˃ 2500g a acurácia de teste foi 98% sob área da curva ROC. As falhas na extubação ocorreram mais nos bebês prematuros (p=0,05), com menor peso ao nascer (p=0,03), e no momento da extubação (p=0,02), com mais de 7 dias de ventilação mecânica (p=0,02), que estavam recebendo algum tipo de sedação no momento da extubação (p<0,01) e tinham persistência do canal arterial hemodinamicamente significativo (p=0,01). Conclusão: O teste de respiração espontânea com ventilação de pressão de suporte mínima pode ser capaz de prever sucesso de extubação com excelente acurácia em RN a termo e maiores sendo menos preditivo nos demais. | |
dc.identifier.uri | https://axis.ghc.com.br/handle/123456789/61 | |
dc.language.iso | Português | |
dc.local | Porto Alegre | |
dc.notes | Objectives: To evaluate a Spontaneous Breathing test with minimal support pressure to predict successful extubation of newborn (NB) infants and to identify demographic and clinical variables related to extubation failure. Study design: Observational cohort study. Patients: NB submitted to invasive mechanical ventilation for at least 24 hours and with programmed extubation. Methods: Eligible NB underwent continuous positive airway pressure testing with minimum support pressure for 10 minutes prior to extubation, being monitored during this period and classified as failure in the test in the presence of any of these criteria: bradycardia, decrease in oxygen pulse saturation, increase in respiratory effort or apnea. The test result was not reported. Results: 170 tests were performed. There were 143 successful extubations, of which 138 also passed the test with sensitivity of 96.5% (95% CI: 92.0-98.8). Of the 28 extubations that evolved with extubation failure (16.4%), 16 also failed the test with specificity of 57.1%, (95% CI: 37.2-75.5). The negative predictive value was 72.2% (95% CI: 52.5-91.0). The positive predictive value was 92% (95% CI: 86.1-95.6). %. Among infants with gestational age ˃ 37 weeks and weighing ˃ 2500g the test accuracy was 98% under the area of the ROC curve. Extubation failures occurred more in preterm infants (p = 0.05), with lower birth weight (p = 0.03), with more than 7 days of ventilation (p = 0.02), who were receiving some type of sedation at the time of extubation (p <0.01) and had hemodynamically significant patent ductus (p = 0.01). Conclusion: The spontaneous breath test with minimal support pressure ventilation may be able to predict extubation success with excellent accuracy in term and greater NB being less predictive in the others. | |
dc.publisher | Grupo Hospitalar Conceição | |
dc.publisher.program | PROGRAMA DE PÓS-GRADUAÇÃO EM AVALIAÇÃO DE TECNOLOGIAS PARA O SUS - MESTRADO PROFISSIONAL EM AVALIAÇÃO E PRODUÇÃO DE TECNOLOGIAS PARA O SUS | |
dc.rights | Acesso Aberto | |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 Brazil | en |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/br/ | |
dc.subject | Saúde Pública | |
dc.subject | Brasil | |
dc.subject | Sistema Único de Saúde | |
dc.title | VALIDAÇÃO DE UM TESTE DE RESPIRAÇÃO ESPONTÂNEA PARA PREVER SUCESSO NA EXTUBAÇÃO DE RECÉM-NASCIDOS | |
dc.title.alternative | VALIDATION OF A SPONTANEOUS BREATHING TEST TO PREDICT SUCCESS IN NEWBORN EXTUBATION | |
dc.type | Dissertação |